          1. Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
            Zhejiang Xikai Electric Co. , Ltd.
            Contact
            Zhejiang Xikai Electric Co. , Ltd.
            Mailbox:wzxikai@wzxikai.com
            Tel:+86 577 61666 016
            address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

            product list

            Indoor high voltage load switch
            14/5000 Indoor vacuum circuit breaker
            Outdoor vacuum circuit breaker
            Outdoor high voltage load switch
            Outdoor high voltage disconnector
            Outdoor drop fuse
            High voltage current limiting fuse series
            High voltage complete set
            current position:Home>Product Center

            Product Center

              • Air insulated switchgear (Ring Main Units)

              Air insulated switchgear (Ring Main Units)

              XGN15 SF6 Insulated Ring Main Units is either compact or extensible metal enclosed switchgear, which takes SF6 Load Break Switch as main switch and whole cell insulated by air, it is suitable for distribution automation, with characteristics of simple structure, easy operation, reliable interlock and easy installation. The switchgear can be supplied satisfied technical program direct at different service condition and different uses' requirement. Adopting of sensor technology and newest relay protection, with the addition of advanced technical characteristics and easy erection scheme, it is completely meet the requirements of ever-changing market. XGN15 SF6 Insulated Ring Main Units takes FL( R)N36 or FL( R)N48 SF6 Load Break Switch made by Xikai as main switch, also can be installed with VS1 VCB with international highest technical level, or VSG according the requirements of users. The operation of main switch is manual or motorized, to be coupled with FTU or RTC, can meet the requirements of remote control, distant signal, remote inspection.

              Technical Information

              Technical Specification

               

               

               

               

               

              Item

               

              Unit

              Load Break Switch Unit

               

              LBS-Fuse Combination Unit

              Vacuum Circuit Breaker Unit

              Rated Voltage

               

              kV

              12/24

               

              12/24

              12/24

              Rated Power Frequency

               

              Hz

              50/60

               

               

               

              Rated Current

              Main Busbar

              A

              630

               

               

               

              Branch Busbar

               

              630

               

              (depend on rated current of fuse)

              630

              Power Frequency

               

              To Earth And Between Poles

              kV

               

              42/55

               

              Withstand Voltage 50hz 1min

               

              Across Isolating Distance

              kV

               

              48/70

               

              Impulse Withstand Voltage1.2/50μs

               

              To Earth And Between Poles

              kV

               

              75/125

               

               

               

              across Isolating Distance

              kV

               

              85/145

               

               

               

               

              Main Circle

              kA

              20/3s

               

              -

              25/2s

              Short Time Withstand Current

               

               

              Earthing Circle

              kA

              20/2s

               

              -

              25/2s

              Rated Peak Withstand Current

              kA

              62.5/50

               

              -

              63/50

              Rated Short-circuit Breaking Capacity

              kA

               

              67/50

               

              rated Transfer Current

               

              A

              -

               

              1700

              -

              Rated On Load Breaking Current

              A

              630

               

              -

              -

              rated Close Loop Breaking Current

              A

              630

               

              -

              630

              rated Cable Charging Current

              A

              10

               

              -

              15

              Protection Level

               

               

               

               

              IP3X

               

              Mechanism Endurance

               

               

              LBS

              cycles

              5000

               

              5000

              10000

               

               

               

              ES

              cycles

              2000

               

              2000

              2000


              Overall and installation dimensions

              ?