          1. Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
            Zhejiang Xikai Electric Co. , Ltd.
            Contact
            Zhejiang Xikai Electric Co. , Ltd.
            Mailbox:wzxikai@wzxikai.com
            Tel:+86 577 61666 016
            address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

            product list

            Indoor high voltage load switch
            14/5000 Indoor vacuum circuit breaker
            Outdoor vacuum circuit breaker
            Outdoor high voltage load switch
            Outdoor high voltage disconnector
            Outdoor drop fuse
            High voltage current limiting fuse series
            High voltage complete set
            current position:Home>Product Center

            Product Center

              • GW5-40.5W Outdoor High Voltage Ac Disconnector

              GW5-40.5W Outdoor High Voltage Ac Disconnector

              GW5-40.5 series outdoor high-voltage AC isolating switch (hereinafter referred to as “isolation switch”) is an outdoor high-voltage electrical equipment with a frequency of 50Hz. It is used for the connection of high-voltage lines under voltage and no load, and for the high-voltage busbars being repaired. Electrical equipment such as circuit breakers can be electrically isolated from live high-voltage lines. It can also be used to separate small capacitive currents and inductor currents. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T 486-2010 "High Voltage AC Isolation Switch and Grounding Switch" and other technical standards

              Technical Information

              Technical Specification

               

               

               

               

               

               

               

              Rated voltage

              kV

               

              40.5

               

               

              Rated frequency

              H

               

              50

               

               

              Rated current

              A

              630

               

              1250

               

              2000

              Rated short-time withstand current

              kA

              20/25

               

              25/31.5

               

              31.5

              Rated short-time withstand current (peak)

              kA

              50/63

               

              63/80

               

              80

              Rated short-time power frequency withstand voltage

              kV/min

              95/1nterphase, earth, dry test

              118/1nterphase, earth, dry test

              95/1nterphase, ground, and wet test

              Rated lightning impulse withstand voltage

              kV

              185/1 earth

              215 Fracture

              Rated short-time withstand current duration

              S

              4 Isolation switch、

              2Grounding switch

              Creepage distance

              mm

              ≥1256Class e antifouling

               

              Main loop resistance

              μΩ

              ≤100

               

               

               

              ≤80

               

              Operating mechanism

              Human operating agency

               

              CS17-G5 Without grounding switch

               

              Main knife Cs17-G5, ground knife Cs17-G2 (with single/double earthing switch)

              Motor operating mechanism

               

              CJ6 type, motor voltage AC380V or DC220V, control voltageAC220V or DC220V, auxiliary contact 8 normally open 8 nor mally closed (standard)

              Mechanical life

              Times

               

              Isolation switch grounding switch


              Overall and installation dimensions