          1. Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
            Zhejiang Xikai Electric Co. , Ltd.
            Contact
            Zhejiang Xikai Electric Co. , Ltd.
            Mailbox:wzxikai@wzxikai.com
            Tel:+86 577 61666 016
            address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

            product list

            Indoor high voltage load switch
            14/5000 Indoor vacuum circuit breaker
            Outdoor vacuum circuit breaker
            Outdoor high voltage load switch
            Outdoor high voltage disconnector
            Outdoor drop fuse
            High voltage current limiting fuse series
            High voltage complete set
            current position:Home>Product Center

            Product Center

              • (H) GW9-12 Outdoor High Voltage Ac Disconnector

              (H) GW9-12 Outdoor High Voltage Ac Disconnector

              (H) GW9-12 series outdoor high-voltage AC single-phase isolating switch (hereinafter referred to as "isolation switch"), for 10kV line to be exchanged under voltage and no load, as well as for high-voltage busbars, circuit breakers and other electrical equipment to be repaired Electrically isolated from live high voltage lines. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T486-2010 (High Voltage AC Isolation Switch and Grounding Switch) and other technical standards.

              Technical Information

              Technical Specification

               

               

               

              Rated frequency

               

              Hz

              50

              Rated voltage

               

              kV

              12

              Rated current

               

              A

              630(250)

              Rated short-time withstand current and duration

              kA/s

              20(25)/4

              Rated peak withstand current

              kA

              50(63)

              Rated short-time power frequency withstand voltage

               

              Interphase and ground (dry test)

              kV/min

              42/1

               

              Fracture (dry test)

              kV/min

              48/1

               

              Phase to ground (wet test)

              kV/min

              30/1

               

              Fracture (wet test)

              kV/min

              36/1

               

              Lightning impulse withstand voltage

               

              Phase to ground

              kV

              75

               

              Fracture

              kV

              85

              Loop resistance

               

              μΩ

              ≤80

              Mechanical life

               

              Times

              3000

              Pollution level

               

               

              e Class

              Creepage distance

               

              mm

              ≥372