          1. Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
            Zhejiang Xikai Electric Co. , Ltd.
            Contact
            Zhejiang Xikai Electric Co. , Ltd.
            Mailbox:wzxikai@wzxikai.com
            Tel:+86 577 61666 016
            address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

            product list

            Indoor high voltage load switch
            14/5000 Indoor vacuum circuit breaker
            Outdoor vacuum circuit breaker
            Outdoor high voltage load switch
            Outdoor high voltage disconnector
            Outdoor drop fuse
            High voltage current limiting fuse series
            High voltage complete set
            current position:Home>Product Center

            Product Center

              • FZW32 outdoor high voltage isolation vacuum load switch

              FZW32 outdoor high voltage isolation vacuum load switch

              FZW32 Outdoor Vacuum Load Break Switch is used for power system, it is suitable for 12kV 50Hz three-phase power system. The frame of this switch is applied with the stainless steel or steel with hot-dip galvanization and anti-UV coating. All the elements are used the stainless steel. To make sure the stable and perfect function of the switch.

              Technical Information

              Technical Specification

               

               

               

               

              Rated voltage

               

              kV

              12

              40.5

              Rated frequency

               

              Hz

              50

              50

              Rated current

               

              A

              630

              1250

              Rated active load breaking current

              A

              630

              1250

              Rated closed-loop breaking current

              A

              630

              1250

              5% rated active load breaking current

              A

              31.5

              62.5

              Rated cable charging breaking current

              A

              10

              25

              Rated no-load transformer breaking capacity

              kVA

              1600

              1600

              Rated breaking capacitor bank current

              A

              100

              100

              1min power frequency withstand voltage: vacuum fracture, phase, relative / isolation fracture

              kV

              42/48

              68/95/110

              Lightning impulse withstand voltage: phase-to-phase, relative/isolated fracture

              kV

              75/85

              185/215

              ated short-time withstand current (thermal stability)

              kA

              20

              25

              Rated short circuit duration

              S

              4

              4

              ated peak withstand current (dynamic stability)

              kA

              50

              63

              Rated short circuit closing current

              kA

              50

              63

              Mechanical life

               

              Times

              10000

              10000

              Vacuum arcing contacts allow wear thickness

              mm

              0.5

              0.6

              Manual operating torque

               

              N.m

              ≤200

              ≤300

               

               

              Contact opening distance

              mm

               

              5±1

               

               

              Average opening speed

              m/s

               

              1.1±0.2

               

               

              Three-phase opening

              ms

               

              ≤5

              Load switch vacuum interrupter assembly adjustment

               

              Three-phase closing

              ms

               

              ≤2

               

               

              Charged body and relative distance

              mm

               

              >200

               

               

              Auxiliary loop resistance

              μΩ

               

              ≤300


              Overall and installation dimensions